Help Center
battery

Parameter Interpretation

"Battery" indicates a battery module.

Basic

  • timeoutThrowError

Description: Battery timeout error time.

Note: The battery timeout error period (unit: s) can be adjusted according to the actual situation.

  • chargeCount

How many times in a row will the device be charged?

Note: How many consecutive times are considered as charging? The default value is 0, indicating that it is disabled. The detection count is once per second.

  • lowVoltage

Description: Battery low voltage alarm threshold.

Note: This parameter is used to set the minimum battery voltage alarm threshold. By default, this parameter is disabled (-1).

  • temperatureThreshold

Temperature Alarm Limits

Note: The temperature alarm limit is not enabled by default. The unit of measurement is Celsius.

  • WarningPercentage

Definition: Percentage of Battery Alarms

Note: This indicates the threshold for the low battery capacity alarm.

  • Error Percentage

Percentage of Battery Errors

Note: This is used to indicate when the battery power is low and report an error.

  • shutdownPercentage

Percentage of batteries turned off

Note: The default value is -1.

Brand

  • Brand

Definition: Various brands of batteries

Note: Battery brands may have different protocols. Please select the appropriate battery protocol based on the actual brand and protocol.

Voltage

  • Voltage

The Voltage of a Battery

Note: Please select the appropriate battery voltage based on the current battery status.

Capacity

  • Capacity

What it means: Battery capacity

Note: Choose the battery capacity according to the current battery status

Percentage Calculator

  • byProtocol

What it means: Retrieve battery information using BMS

Note: To obtain accurate battery information from the BMS, select the appropriate option based on the current battery condition.

  • byVoltage

Get battery information by measuring voltage.

Note: To obtain battery information, calculate the voltage and select the appropriate battery based on the current battery situation.

Type

  • RS485

Interpretation: Battery communication mode via RS485 communication

Note: The battery communication mode is RS485. Please select the appropriate terminator based on the actual battery conditions.

  • RS232

The communication mode for batteries is via RS232 communication.

Note: The communication mode of the battery is RS232. Please select the appropriate option based on the actual situation of the battery.

  • CAN

The communication mode for batteries is through CAN.

Note: The battery communication mode is CAN. Please select the appropriate mode based on the current battery condition.

  • canport

Definition: Battery CAN communication port

Note: The communication mode of the battery is CAN. The hardware circuit through which the battery connects can be selected according to the actual battery situation.

Baudrate

  • Baud rate

Definition: When selecting RS485 or RS232 communication, specify the baud rate.

Note: When selecting a baud rate for RS485 or RS232 communication, choose the rate based on the current battery conditions.

Configuration FAQ

Last updated 2023/05/04
Article content

Parameter Interpretation

Basic

Brand

Voltage

Capacity

Percentage Calculator

Type

Baudrate

Configuration FAQ