Help Center
Back Home
Serial port server
Composite robot terminal device
Composite robot terminal device
Furui H100

Fairchild utilizes the Furui H100 lidar for navigation and the Furui C200 for obstacle avoidance.

1. Instructions for Configuration

Before using Furui Lidar, the IP and port number of the lidar need to be configured using the upper computer of Furui.
Download Furui h100.zip
Power on the lidar and connect it to the PC through the network cable. Open the upper computer software and click "Basic Information" on the left. Enter the radar IP address and click "Connect". After the radar is connected, the host displays the device name, device serial number, device version, and MAC address. The default IP address of the Furui H100 is 192.168.0.240. You need to change the IP address of the PC to the same network segment.

Once connected, click "Config - Radar Permission Unlock". You need to change the IP address and scanning frequency to an angular resolution.

According to Xiangong Intelligence, the lidar IP should be set to 192.168.192.10x, and the corresponding subnet mask and gateway should be modified. Click "Modify" and save.

Then change the speed and angular resolution to 30Hz/0.1°. Click "Modify" and save.

After that, the lidar needs to be powered off and restarted before it can be configured for use in Roboshop.

2. Usage Instructions

If you want to use the Freui h100/c200 with Sengong's controller, you'll need to configure it using roboshoop in the robot model.

To use FocusRay-c200-TCP, select FocusRay-h100-TCP in the brand section of the above figure. For FocusRay-H100-TCP, select FocusRay-H100-tcp. Fill in the configured IP and port number, check enable device and push, and you'll be able to use the lidar.
The other parameters are described in the table below.

Keyword

Description

Value

ID

ID of the laser connected to the controller, starting from 0

0

X

X coordinates for laser installation

Set this parameter based on the actual installation position

Y

The Y coordinate of the laser installation

Set this parameter based on the actual installation position

Z

Laser mounting height

Set this parameter based on the actual installation position

Yaw

Orientation of laser mounting

Set this parameter based on the actual installation position

Step

Laser resolution

0.1

Minimum Angle

Minimum angle of detection

Set this parameter based on the actual detection range

Maximum Angle

Maximum angle detected

Set this parameter based on the actual detection range

Upside

Formal or not

Set this parameter based on the actual installation situation

Use for Localization

Whether it is used for locating

Set this parameter based on the actual function. Default value

IP

IP address of the laser. The default value is from192.168.192.100To start, multiple lasers line up in the back192.168.192.101,192.168.192.102

192.168.192.100(Fill in as actual)

Port

Port used by the laser

Actual filling

Brand

Laser brand

FocusRay-h100-TCP

Com

Connected Com

ttyUSB0

Last updated 2023/05/03
Article content
  1. Instructions for Configuration
  1. Usage Instructions